Run II Luminosity Monitor

[ Home | Members | Detector | Electronics | Trigger | Online | Database | Measurements ]

Detector


Design Overview

The D0 Run II Luminosity Monitor consists of two arrays of plastic scintillation counters located on the inside faces of the end-cap calorimeters, ~135 cm from the center of the D0 detector along the z direction (beam axis), and arranged symmetrically about the beam pipe. The detector covers a region in the pseudorapidity of 2.7 < |h| < 4.4.

Each of the Luminosity Monitor arrays consists of 24 identical 5/8'' thick BC-408 scintillator wedges, with Hamamatsu 1'' diameter fine-mesh photomultiplier tubes (R5505) mounted directly on the faces. The counters will be located in a region where the magnetic field maps indicate a nearly axial magnetic field of ~ 1 Tesla.

 Index of documents

Back to Top


This work is supported by the Brown University and by the Department of Energy.
For problems or questions regarding this web contact cmiao@hep.brown.edu.
Last updated: June 10, 1999.